8.MULTI-PATH CONTROL B-63943EN-1/02
- 862 -
- Item for a 2-path interference check only
NOTE
Besides the common items, there is a note on a
2-path interference check only.
If, during a path interference check, the tool posts of
the two paths are judged to have interfered with each
other, both the paths are decelerated to a stop and
the control unit enters the alarm state. If this occurs,
the path interference alarm signal TIALM (F0064#7)
is set to "1" to notify that an alarm has occurred in a
path interference check.
- Item for a multi-path interference check only
NOTE
Besides the common items, there is a note on a
multi-path interference check only.
If, during a path interference check, the tool posts of
the paths associated with the Gn406 and Gn407
signals of each path are judged to have interfered
with each other, all the paths associated are
decelerated to a stop, and the paths related to the
interference (paths in which movement was in
progress) enter the alarm state. Other associated
paths enter the operation pause state. If this
occurs, the tool post interference alarm signal TIALM
(Fn064#7) of the path related to the interference is
set to "1" to notify that a check has occurred in a path
interference check.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1300 BFA
[Input type] Setting input
[Data type] Bit path
# 7 BFA When the stored stroke check 1, 2, or 3 alarm is issued, an interference
alarm is issued with the inter-path interference check function (T
series), or a chuck/tail stock barrier (T series) alarm is issued:
0: The tool stops after entering the prohibited area.
1: The tool stops before the prohibited area.