B-63943EN-1/02 1.AXIS CONTROL
- 205 -
8333 Synchronization error zero width for each axis
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 1 to 32767
When a synchronization error below the value set in this parameter is
detected, synchronization error compensation is not performed.
Set this parameter with a slave axis.
8334 Synchronization error compensation gain for each axis
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 1 to 1024
This parameter sets a synchronization error compensation gain.
Compensation pulses found by the following expression are output for
the slave axis:
Compensation pulses = Synchronization error × (Ci/1024)
Ci: Compensation gain
Set this parameter with a slave axis.
8335 Synchronization error zero width 2 for each axis
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter sets synchronization error zero width 2 for
synchronization error smooth suppression.
Set this parameter with a slave axis.
NOTE
Set a value less than the value set in parameter
No. 8333.
8336 Synchronization error compensation gain 2 for each axis
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1024
This parameter sets synchronization error compensation gain 2 for
synchronization error smooth suppression.
Set this parameter with a slave axis.