B-63943EN-1/02 12.TOOL FUNCTIONS
- 1601 -
Signal
Tool change signal TLCH<Fn064#0>,TLCH1 to 4<Fn328#0 to #3>
[Classification] Output signal
[Function] These signals post that the life of the last one of the tools having the
same tool type number has expired.
[Output condition] These signals turn to "1" in the following cases:
- When the life of the last one of the tools having the same tool
type number has expired
- When the last one of the tools having the same tool type number
is treated as a broken tool by tool skip signal TLSKP
These signals turn to "0" in the following cases:
- When the tool change reset signal is set to "1".
NOTE
1 This signal is provided for each spindle position.
2 F64#0 is output signals for the first spindle.
Tool change reset signal TLRST<Gn048#7>,TLRST1 to 4<Gn328#0 to #3>
[Classification] Input signal
[Function] These signals set the tool change signal to "0".
[Output condition] When the signals are set to 1, the control unit operates as follows:
- Setting the tool change signal to "0"
NOTE
1 Tool change signal TLCH is not cleared by reset.
2 This signal is provided for each spindle position.
3 G48#7 is input signals for the first spindle.
Individual tool change signals TLCHI<Fn064#2>,TLCHI1 to 4<Fn328#4 to #7>
[Classification] Output signal
[Function] Reports the end of the life of the current tool.
[Output condition] These signals turn to "1" in the following cases:
- The end of the life of the current tool is detected.
These signals turn to "0" in the following cases:
- Individual tool-change reset is executed.
NOTE
1 This signal is provided for each spindle position.
2 F64#2 is output signals for the first spindle.
Individual tool change reset signals TLRSTI<Gn048#6>,TLRSI1 to 4<Gn328#4 to #7>
[Classification] Input signal
[Function] Sets the individual tool change signal TLCHI to "0".
[Operation] When the signals are set to "1", the control unit operates as follows:
- Sets the individual tool change signal to "0".