14.DISPLAY/SET/EDIT B-63943EN-1/02
- 1812 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3290 KEY
[Input type] Parameter input
[Data type] Bit path
# 7 KEY For memory protection keys:
0: The KEY1, KEY2, KEY3, and KEY4 signals are used.
1: Only the KEY1 signal is used.
NOTE
1 The functions of the signals depend on whether
KEY=0 or KEY=1.
When KEY = 0:
- KEY1: Enables a tool offset value, workpiece zero
point offset value, and workpiece shift
value to be input.
- KEY2: Enables setting data, macro variables, and
tool life management value to be input.
- KEY3: Enables program registration and editing.
- KEY4: Enables PMC data (counter and data
table) to be input.
When KEY = 1:
- KEY1: Enables program registration and editing,
and enables PMC parameter input.
- KEY2 to KEY4: Not used
2 When a multi-path system is used, the setting for
path 1 is followed.