11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1344 -
NOTE
2. When the first spindle is SA, the second spindle is S, and 1 is set for the first
spindle and 2 is set for the second spindle in parameter No. 3781
If bit 2 (MPA) of parameter No. 3706 is 0
N10 M03;
N20 SA100; → 100 is specified for 1st spindle.
N30 S200P1; → 200 is specified for 2nd spindle.
N40 S300; → 300 is specified for 2nd spindle.
N50 S200P2; → 200 is specified for 2nd spindle.
N60 S300; → 300 is specified for 2nd spindle.
N70 SA400; → 400 is specified for 1st spindle.
N80 S500; → 500 is specified for 2nd spindle.
If bit 2 (MPA) of parameter No. 3706 is 1
N10 M03;
N20 SA100; → 100 is specified for 1st spindle.
N30 S200P1; → 200 is specified for 2nd spindle.
N40 S300; → 300 is specified for 2nd spindle.
N50 S200P2; → 200 is specified for 2nd spindle.
N60 S300; → 300 is specified for 2nd spindle.
N70 SA400; → 400 is specified for 1st spindle.
N80 S500; → 500 is specified for 2nd spindle.
Example
- Example of setting spindle names when extended spindle names
are used
No.3738=0,No.3739=0 → ‘S’
No.3738=65,No.3739=0 → ‘SA’
No.3738=66,No.3739=65 → ‘SBA’
No.3738=49,No.3739=0 → ‘S1’
No.3738=49,No.3739=48 → ‘S10’
No.3738=0,No.3739=65 → ‘S’
- Specifying spindle names that end with a numeric character
S1=100
S11=200
- Specifying spindle names that end with an alphabetical character
S100 or S=100
SB200 or SB=200
SBB300 or SBB=300