B-63943EN-1/02 4.REFERENCE POSITION ESTABLISHMENT
- 507 -
Each signal is set to 0 when:
- The torque limit is not reached for the corresponding axis during
cycle operation for reference position setting with mechanical
stopper.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Fn180 CLRCH8 CLRCH7 CLRCH6 CLRCH5 CLRCH4 CLRCH3 CLRCH2 CLRCH1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 5 ZMIx The direction of manual reference position return is:
0: + direction
1: - direction
7181
First withdrawal distance in reference position setting with mechanical
stopper
7182
Second withdrawal distance in butt-type reference position setting with
mechanical stopper
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
This parameter sets a distance an axis in each cycle operation, along
which withdrawal is performed after the mechanical stopper is hit
(distance from the mechanical stopper to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of
parameter No. 1006. Cycle operation cannot be
started if the opposite direction is set.