1.AXIS CONTROL B-63943EN-1/02
- 60 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1817 SBL
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 2 SBL Smooth backlash compensation is :
0: Disabled.
1: Enabled.
1846 Distance for starting the second stage of smooth backlash compensation
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set the distance from the point where the axis
movement direction is reversed to the point where the second stage of
smooth backlash compensation is started.
If the following condition is not satisfied, smooth backlash
compensation is disabled:
Value of parameter No. 1846 ≥ 0
Value of parameter No. 1846 < value of parameter No. 1847
1847 Distance for ending the second stage of smooth backlash compensation
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set the distance from the point where the axis
movement direction is reversed to the point where the second stage of
smooth backlash compensation is ended.
If the following condition is not satisfied, smooth backlash
compensation is disabled:
Value of parameter No. 1846 ≥ 0
Value of parameter No. 1846 < value of parameter No. 1847