B-63943EN-1/02 4.REFERENCE POSITION ESTABLISHMENT
- 477 -
NOTE
1 To this feedrate setting (100%), a rapid traverse
override (F0, 25, 50, or 100%) is applicable.
2 For automatic return after completion of reference
position return and machine coordinate system
establishment, the normal rapid traverse rate is used.
3 As a manual rapid traverse rate before machine
coordinate system establishment by reference
position return, the jog feedrate or manual rapid
traverse rate can be selected with bit 0 (RPD) of
parameter No. 1401.
Before coordinate
system
establishment
After coordinate
system
establishment
Automatic reference
position return (G28)
No.1428 No.1420
Automatic rapid
traverse (G00)
No.1428 No.1420
Manual reference
position return *1
No.1428 No.1428 *3
Manual rapid
traverse
No.1423 *2 No.1424
4 When parameter No. 1428 is set to 0, the following
parameter-set feedrates are applied.
Before coordinate
system
establishment
After coordinate
system
establishment
Automatic reference
position return (G28)
No.1420 No.1420
Automatic rapid
traverse (G00)
No.1420 No.1420
Manual reference
position return *1
No.1424 No.1424 *3
Manual rapid
traverse
No.1423 *2 No.1424
1420: rapid traverse rate
1423: Jog feedrate
1424: Manual rapid traverse rate
*1 : By using bit 2 (JZR) of parameter No. 1401, the
jog feedrate can be used for manual reference
position return at all times.
*2 : When bit 0 (RPD) of parameter No. 1401 is set to
1, the setting of parameter No. 1424 is used.
*3 : When rapid traverse is used for reference position
return without dogs or manual reference position
return after reference position establishment,
regardless of the deceleration dog, the feedrate
for manual reference position return based on
these functions is used (the setting of bit 1 (DLF)
of parameter No. 1404 is followed).