B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1333 -
NOTE
The torque limit override function by address Q
(when bit 4 (TQO) of parameter No. 1802 is set to 1)
is disabled for Cs contour control axes. PMC
sequence programs must be created so that Cs
contour control axes are always placed in the torque
limit state before the G31 P99/P98 is specified.
(Sample program)
O0012
:
Mxx (Specify torque limit from PMC)
:
G31 P99 C200.F100. (Torque limit skip command)
:
Mxx (Cancel torque limit from PMC)
:
M30
Signal
Torque limit command signal (serial spindle) TLMHA<Gn070#1> : First spindle
TLMHB<Gn074#1> : Second spindle
TLMHC<Gn204#1> : Third spindle
TLMHD<Gn266#1> : Fourth spindle
[Classification] Input signal
[Function] These signals limit the output torque of the corresponding serial
spindle to the value set in parameter No. 4025. To cause a torque
limit skip for a Cs contour control axis, set this signal to 1. For
details, refer to the relevant manual of the serial spindle.
Load detection signal (serial spindle) LDT1A<Fn045#4> : First spindle
LDT1B <Fn049#4> : Second spindle
LDT1C <Fn168#4> : Third spindle
LDT1D <Fn266#4> : Fourth spindle
[Classification] Output signal
[Function] These signals are output when the load on the corresponding serial
spindle has reached the value set in parameter No. 4026.
For details, refer to the relevant manual of the serial spindle.
Torque limit state signal (serial spindle) TLMA<Fn045#6> : First spindle
TLMB <Fn049#6> : Second spindle
TLMC <Fn168#6> : Third spindle
TLMD <Fn266#6> : Fourth spindle
[Classification] Output signal
[Function] These signals are output when the torque is being limited by the
corresponding torque limit command signal.
For details, refer to the relevant manual on the serial spindle.