B-63943EN-1/02 1.AXIS CONTROL
- 91 -
A minimum interval where multiple compensation pulses are not
output at a time is determined by the following expression:
Minimum pitch error compensation point interval = (Fmax/7500) ×
(Pmax+1)
Fmax: Maximum feedrate
Pmax: Maximum pitch error compensation value
Example:
When the maximum feedrate is 15000 mm/min, and the
maximum pitch error compensation value is 7 pulses, the
minimum compensation point interval is 16mm.
NOTE
Interpolation type pitch error compensation cannot
be used with spindle positioning.
Note
NOTE
1 This function is an option function.
2 Stored pitch error compensation option is
necessary to use this function.
3 This function is available in bi-directional pitch error
compensation.