8.MULTI-PATH CONTROL B-63943EN-1/02
- 894 -
# 6 SPE The synchronization deviation is:
0: The difference between the positioning deviation of the master
axis and that of the slave axis.
1: The difference between the positioning deviation of the master
axis and that of the slave axis plus the acceleration/deceleration
delay.
NOTE
1 When the master and slave axes have different
acceleration/deceleration time constants, set 1.
2 SPE is valid when bit 1 (SERx) of parameter No. 8162
is set to 1. SPE is used to find a synchronization
deviation for comparison with parameter No. 8181.
# 7 NRS When the system is reset, synchronous, composite, or superimposed
control is:
0: Released.
1: Not released.
#7 #6 #5 #4 #3 #2 #1 #0
8161 NSR CRZ NMR
[Input type] Parameter input
[Data type] Bit
# 0 NMR When an axis subject to composite control is placed in servo-off state:
0: Composite control is stopped
1: Composite control is not stopped, provided bit 0 (FUP) of
parameter No.1819 is set to 1 to disable follow-up for the axis.
# 5 CRZ If the state of the composite control signal is switched in composite
control on two axes under Cs contour control, the reference position
establishment state of the two axes in composite control is:
0: Maintained. (The unestablished state is not assumed.)
1: Assumed to be unestablished.
# 7 NSR When servo-off occurs with an axis in synchronous control:
0: Synchronous control is canceled.
1: Synchronous control is not canceled if follow-up operation is
disabled for the axis (with bit 0 (FUPx) of parameter No. 1819
set to 1).