1.AXIS CONTROL B-63943EN-1/02
- 82 -
- Setting and displaying data
All the compensation data can be displayed and set on the
conventional screen for the pitch error compensation data.
And those data can be input and output by the following methods.
- Input by MDI
- Input by G10
- Input and output by input/output device interface
- Input by PMC window (function code 18)
(It is not possible to input and output by the method other than the
above methods.)
Output format : The output format is as follows:
N20000 P.... ;
N21023 P.... ;
N23000 P.... ;
N24023 P.... ;
N : Pitch error compensation point No. + 20000
P : Pitch error compensation data
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3605 BDPx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 BDPx Both-direction pitch error compensation is:
0: Not used.
1: Used.
3620
Number of the pitch error compensation position for the reference position
for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1535
Set the number of the pitch error compensation position for the
reference position for each axis.