1.AXIS CONTROL B-63943EN-1/02
- 38 -
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Yxxx HPS08 HPS07 HPS06 HPS05 HPS04 HPS03 HPS02 HPS01
Yxxx+1 HPS16 HPS15 HPS14 HPS13 HPS12 HPS11 HPS10 HPS09
xxx indicates the address set using parameter No. 8565.
When bit 0 (HPF) of parameter No. 8501 is set to 1, the signal
addresses are F293 and F294. (Y signal addresses are not used.)
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
8500 HPE
[Input type] Parameter input
[Data type] Bit path
# 7 HPE The maximum number of high-speed position switches is:
0: 6.
1: 16.
#7 #6 #5 #4 #3 #2 #1 #0
8501 HPS HPF
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 HPF The output signal of a high-speed position switch is output to:
0: Address Y.
1: Address F.
# 1 HPS The current position used with the high-speed position switch:
0: Considers a servo error.
1: Does not consider a servo error.
#7 #6 #5 #4 #3 #2 #1 #0
8504 E08 E07 E06 E05 E04 E03 E02 E01
8505 E16 E15 E14 E13 E12 E11 E10 E09
[Input type] Parameter input
[Data type] Bit path
E01 to E09 corresponding high-speed position switch is:
0: Enabled.
1: Disabled (A high-speed position switch always outputs 0).