4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 470 -
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx DIAx ROSx ROTx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
ROTx, ROSx Setting linear or rotation axis.
ROSx ROTx Meaning
0 0
Linear axis
(1) Inch/metric conversion is done.
(2) All coordinate values are linear axis type. (Is not rounded in 0 to 360_)
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
0 1
Rotation axis (A type)
(1) Inch/metric conversion is not done.
(2) Machine coordinate values are rounded in 0 to 360_. Absolute coordinate values are rounded or not
rounded by parameter No.1008#0(ROAx) and #2(RRLx).
(3) Stored pitch error compensation is the rotation type. (Refer to parameter No.3624)
(4) Automatic reference position return (G28, G30) is done in the reference position return direction and the
move amount does not exceed one rotation.
1 1
Rotation axis (B type)
(1) Inch/metric conversion, absolute coordinate values and relative coordinate values are not done.
(2) Machine coordinate values, absolute coordinate values and relative coordinate values are linear axis
type. (Is not rounded in 0 to 360_).
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
(4) Cannot be used with the rotation axis roll over function and the index table indexing function (M series)
Except for the above. Setting is invalid (unused)
# 3 DIAx The move command for each axis is based on:
0: Radius specification
1: Diameter specification
# 5 ZMIx The direction of manual reference position return is:
0: + direction