B-63943EN-1/02 1.AXIS CONTROL
- 83 -
3621
Number of the pitch error compensation position at extremely negative
position for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1535
Set the number of the pitch error compensation position at the
extremely negative position for each axis.
3622
Number of the pitch error compensation position at extremely positive
position for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 1535
Set the number of the pitch error compensation position at the
extremely positive position for each axis.
This value must be larger than set value of parameter (No.3620).
3623 Magnification for pitch error compensation for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 100
Set the magnification for pitch error compensation for each axis.
If the magnification is set to 1, the same unit as the detection unit is
used for the compensation data.