B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1439 -
Alarm and message
Number Message Description
PS0200 ILLEGAL S CODE COMMAND In the rigid tap, an S value was out of range or was not
specified. The parameter (Nos. 5241 to 5243) setting is an S
value which can be specified for the rigid tap.
PS0201 FEEDRATE NOT FOUND IN RIGID
TAP
The command F code for a cutting feedrate is a zero.
If the value of F command is much smaller than that of the S
command, when a rigid tap command is specified, this alarm is
generated. This is because cutting is not possible by the lead
specified by the program.
PS0202 POSITION LSI OVERFLOW In the rigid tap, spindle distribution value is too large. (System
error)
PS0203 PROGRAM MISS AT RIGID TAPPING In the rigid tap, position for a rigid M code (M29) or an S
command is incorrect. Modify the program.
PS0204 ILLEGAL AXIS OPERATION In the rigid tap, an axis movement is specified between the
rigid M code (M29) block and G84 (or G74) block. Modify the
program.
PS0205 RIGID MODE DI SIGNAL OFF Although a rigid M code (M29) is specified in rigid tapping, the
rigid mode DI signal (DGN G061.0) is not ON during execution
of the G84 (or G74) block. Check the PMC ladder diagram to
find the reason why the DI signal is not turned on.
PS0206 CAN NOT CHANGE PLANE (RIGID
TAP)
Plane changeover was instructed in the rigid mode. Modify the
program.
PS0207 RIGID DATA MISMATCH The specified distance was too short or too long in rigid
tapping.
SV0410 EXCESS ERROR (STOP) The amount of positional deviation during stopping exceeded
the parameter (No. 1829) setting value.
In a dual check safety function, an alarm occurs during safety
monitoring (when the safety monitoring start signal SEV or SEP
is 1), but the alarm cannot be canceled by a reset.
SV0411 EXCESS ERROR (MOVING) The amount of positional deviation during traveling became
excessive than the parameter setting value. (Generally, in the
parameter No.1828, the dual check safety function during
safety monitoring (when he safety monitoring start signal SEV
or SEP is 1) is the parameter No. 1838.)
In a dual check safety function, an alarm occurs during safety
monitoring, but the alarm cannot be canceled by a reset.
SP0740 RIGID TAP ALARM : EXCESS ERROR The positional deviation of the stopped spindle has exceeded
the set value during rigid tapping.
SP0741 RIGID TAP ALARM : EXCESS ERROR The positional deviation of the moving spindle has exceeded
the set value during rigid tapping.
SP0742 RIGID TAP ALARM : LSI OVERFLOW An LSI overflow has occurred for the spindle during rigid
tapping.