B-63943EN-1/02 4.REFERENCE POSITION ESTABLISHMENT
- 487 -
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 5 ZMIx The direction of manual reference position return is:
0: + direction
1: - direction
#7 #6 #5 #4 #3 #2 #1 #0
1007 GRDx
[Input type] Parameter input
[Data type] Bit axis
# 4 GRDx For the axis on which absolute values are detected, when
correspondence between the machine position and the position by the
absolute position detector is not completed, setting of the reference
position without dogs is:
0: Not performed two or more times.
1: Performed two or more times.