B-63943EN-1/02 16.MEASUREMENT
- 1863 -
#7 #6 #5 #4 #3 #2 #1 #0
6201 SKPXE IGX TSE
[Input type] Parameter input
[Data type] Bit path
# 2 TSE When the torque limit skip function (G31 P99/98) is used, the skip
position held in a system variable (#5061 to #5080 (#100151 to
#100182 for a system having more than 20 axes)) is:
0: Position that is offset considering the delay (positional deviation)
incurred by the servo system.
1: Position that does not reflect the delay incurred by the servo
system.
Position during skip operation
Current position of CNC
Machine position
Error amount
Position in consideration of delay
Position without consideration of
dela
Origin of the coordinate system
Stop point
# 4 IGX When the high-speed skip function is used, SKIP, SKIPP, and SKIP2
to SKIP8 are:
0: Enabled as skip signals.
1: Disabled as skip signals.
# 7 SKPXE For the skip function (G31), the skip signal SKIP is:
0: Disabled.
1: Enabled.
Enabling and disabling the skip signals
Parameter
IGX
(No.6201#4)
GSK
(No.6200#0)
SKPXE
(No.6201#7)
Skip signal
SKIPP
Skip signal
SKIP
Multi-step skip
signal
SKIP2-SKIP8
0 0 0 Disabled Enbaled Enbaled
0 1 0 Enbaled Enbaled Enbaled
0 0 1 Disabled Disabled Enbaled
0 1 1 Enbaled Disabled Enbaled
1 0 0 Disabled Disabled Disabled
1 1 0 Disabled Disabled Disabled
1 0 1 Disabled Disabled Disabled
Setting
1 1 1 Disabled Disabled Disabled
IGX (bit 4 of parameter No. 6201) is valid for the skip function (when
HSS (bit 4 of parameter No. 6200) is 1) using the high-speed skip