B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1429 -
#7 #6 #5 #4 #3 #2 #1 #0
5203 RBL OVS RFF
[Input type] Parameter input
[Data type] Bit path
# 2 RFF In rigid tapping, feed forward is:
0: Disabled.
1: Enabled.
# 4 OVS In rigid tapping, override by the feedrate override select signal and
cancellation of override by the override cancel signal is:
0: Disabled.
1: Enabled.
When feedrate override is enabled, extraction override is disabled.
The spindle override is clamped to 100% during rigid tapping,
regardless of the setting of this parameter.
# 5 RBL As acceleration/deceleration for rigid tapping cutting feed:
0: Linear acceleration/deceleration is used.
1: Bell-shaped acceleration/deceleration is used.
5210 Rigid tapping mode specification M code
[Input type] Parameter input
[Data type] 2-word path
[Valid data range] 0 to 65535
This parameter sets an M code that specifies the rigid tapping mode.
The M code is judged to be 29 (M29) when "0" is set.
5211 Override value during rigid tapping extraction
[Input type] Parameter input
[Data type] Word path
[Unit of data] 1% or 10%
[Valid data range] 0 to 200
The parameter sets the override value during rigid tapping extraction.
NOTE
The override value is valid when DOV in parameter
No.5200 #4 is "1". When OVU (bit 3 of parameter
No.5201) is 1, the unit of set data is 10%. An
override of up to 2000% can be applied to extraction.