8.MULTI-PATH CONTROL B-63943EN-1/02
- 834 -
- Assignment of signals
CAUTION
1 When there are four or more paths
Input signals by the X address for each path are
assigned to up to three paths. Therefore, when
there are four or more paths, the signals must be
assigned by XSG (bit 2 of parameter No. 3008).
2 When there are nine or more axes for one path
The X address of the reference position return
deceleration signal (*DECn) for each axis is
assigned to up to three paths (up to eight axes for
each path). Therefore, when there are four or more
paths or there are nine or more axes for one path,
the signals must be assigned by setting XSG (bit 2
of parameter No. 3008), parameter No. 3013, and
parameter No. 3014.
The input signal (G signal) and output signal (F
signal) for each axis are assigned to up to eight axes
for each path. Therefore, when there are nine or
more axes for one path, the signals must be
assigned by setting parameter No. 3021.
Parameter
0980 Machine group number to which each path belongs
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 1 to 3
Set the machine group number to which each path belongs.
NOTE
When 0 is set, each path is assumed to belong to
machine group 1.