B-63943EN-1/02 11.SPINDLE SPEED FUNCTION
- 1215 -
NOTE
This parameter is disabled when an extended spindle
name is used.
3719 Subscript for display of a serial spindle (sub-spindle)
[Input type] Parameter input
[Data type] Byte spindle
[Valid data range] 0 to 122
Set a subscript to be added to spindle speed display on a screen such
as the position display screen.
NOTE
This parameter is disabled when an extended spindle
name is used.
- Connection of serial spindle control unit
#7 #6 #5 #4 #3 #2 #1 #0
4019 PLD
4195 PLD
[Input type] Parameter input
[Data type] Bit spindle
# 7 PLD When power is turned on, spindle amplifier parameters for the serial
spindle are:
0: Not set automatically.
1: Set automatically.
No. 4019 : (Used when the spindle switching function is not used, or
used for the main spindle when the spindle switching
function is used)
No. 4195 : (Used for the sub-spindle when the spindle switching
function is used)
When this parameter is set to 0 after the spindle motor model code
parameter is set, the next power-on operation sets the standard values
for the motor model in parameters and sets this parameter to 0.
4133
Spindle motor model code
(Used when spindle switching function is not used, or used for main spindle
in spindle switching)
4309
Spindle motor model code
(For sub-spindle when spindle switching function is provided)
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 0 to 32767
When setting initial parameters for the serial spindle, specify the
spindle motor model code.