12.TOOL FUNCTIONS B-63943EN-1/02
- 1614 -
13238 Start pot number of the fourth cartridge
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word
[Valid data range] 1to9999
This parameter sets the start pot number to be used with the fourth
cartridge. Pot numbers starting with the value set in this parameter and
sequentially incremented by 1 are assigned to all data items.
13250 Number of valid spindles
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 8
This parameter sets the number of spindle positions usable with the
tool management function.
13251 Number of valid standby positions
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 8
This parameter sets the number of standby positions usable with the
tool management function.
13252 M code for specifying a particular tool
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 65535
This parameter sets not a tool type number but an M code for directly
specifying the T code of a particular tool.