B-63943EN-1/02 1.AXIS CONTROL
- 221 -
#7 #6 #5 #4 #3 #2 #1 #0
1817 TANx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 6 TANx Tandem control
0: Not used
1: Used
NOTE
Set this parameter to both master axis and slave
axis.
#7 #6 #5 #4 #3 #2 #1 #0
2008 VFA
[Input type] Parameter input
[Data type] Bit axis
# 2 VFA In tandem control, the speed feedback average function is:
0: Disabled.
1: Enabled.
2087 Preload value (Tcmd offset)
[Input type] Parameter input
[Data type] Word axis
[Unit of data] (Amplifier limit) / 7282
[Valid data range] -1821 to 1821
This parameter prevents backlash by adding an offset to the torque
command.
Set a value slightly greater than the friction value.
The estimated value is approximately 1/3 of the rated torque.
(Example) When a torque equivalent to 3 A is set in two opposite directions, if
the amplifier limit is 40 A
3 / (40 / 7282) = 546
Master side = 546
Slave side = -546