B-63943EN-1/02 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 717 -
the upper limit of the feedrate for an one-digit F code feed command,
and set it in parameter 1460 or 1461.
Fmax1: Upper limit of the feedrate for F1 to F4 (parameter 1460)
Fmax2: Upper limit of the feedrate for F5 to F9 (parameter 1461)
1451
Feedrate for F1
to
1459
Feedrate for F9
[Input type] Setting input
[Data tye] Real path
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set Feedrates for one-digit F code feed commands F1 to F9.
When an one-digit F code feed command is executed, as the feedrate
is changed by turning the manual pulse generator, these parameter
values also change accordingly.
1460
Upper feedrate limit for F1 to F4
1461
Upper feedrate limit for F5 to F9
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min(machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the upper limit of feedrate for the one-digit F code feed command.
As the feedrate increases by turning the manual pulse generator, the
feedrate is clamped when it reaches the upper limit set. If an one-digit
F code feed command F1 to F4 is executed, the upper limit is that set
in parameter 1460. If an one-digit F code feed command F5 to F9 is
executed, the upper limit is that set in parameter 1461.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Cutting feed