B-63943EN-1/02 8.MULTI-PATH CONTROL
- 981 -
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G062 HEAD2
G063 HEAD
G251 LCBS
G408 HEAD4 HEAD3
Parameter
The following describes those parameters that must be set especially
for loader paths.
#7 #6 #5 #4 #3 #2 #1 #0
0984 LCP
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be turned
off before operation is continued.
# 0 LCP Set whether the path is a loader control path.
0: The path is not a loader control path.
1: The path is a loader control path.
NOTE
1 If the number of paths set as loader paths with this
parameter does not match the number of loader
paths in the system being used, alarm PW0004 is
generated.
2 Path 1 cannot be set as a loader path. If it is
specified as such, alarm PW0004 is generated.