12.TOOL FUNCTIONS B-63943EN-1/02
- 1620 -
- Total maximum life
Item Description
Data length 4byte
Unit of data When the number of use times is specified: Time
When time is specified: Seconds/milliseconds
Valid data range When the number of use times is specified: 0 to
2,147,483,647 time
When time is specified: 0 to 359,999,999 s (99999
hours 59 minutes 59 seconds)
0 to 359,999,999 milliseconds (99 hours 59
minutes 59 seconds 999 milliseconds)
The maximum lives of the same-type tools set on the tool management
data screen (for each tool type number) are totaled for each number of
times or for each time and displayed.
- Number (number of tools)
Item Description
Data length 2byte
Valid data range 1 to maximum number of tools (64, 240, or 1,000)
The numbers of tools of the same types are totaled and displayed.
The maximum number of tools change depending on the options used.
- Total notice life
Item Description
Data length 4byte
Unit of data When the number of use times is specified: Times
When time is specified: Seconds/milliseconds
Valid data range When the number of use times is specified: 0 to
2,147,483,647 times
When time is specified: 0 to 359,999,999 s (99999
hours 59 minutes 59 seconds)
0 to 359,999,999 milliseconds (99 hours 59
minutes 59 seconds 999 milliseconds)
The notice lives of same-type tools set on the tool management data
screen (for each tool type number) are totaled for each number of
times or for each time and displayed.
- Status
Item Description
Data length 1byte
Data details 0: --
1: Notice
The status indicating whether the tool life arrival signal has been
output is displayed.
- Sort function
On the total life data screen, sorting in either ascending or descending
order is possible with the following data:
- Tool type number
- Total remaining life