B-63943EN-1/02 18.EMBEDDED ETHERNET FUNCTION
- 2057 -
18.2 SETTING UP THE EMBEDDED ETHERNET FUNCTION
This section describes the setting of parameters for the embedded
Ethernet function.
18.2.1 Parameter Setting of the FOCAS2/Ethernet Function
This subsection describes the settings required to operate the
FOCAS2/Ethernet function.
Notes on using the FOCAS2/Ethernet function for the first time
NOTE
1 When running user's original application software
created by using the FOCAS2/Ethernet function, use
the built-in Ethernet port.
2 The FOCAS2/Ethernet function allows up to five
FOCAS2/Ethernet clients to be connected to one
CNC.
3 Concurrent access by multiple applications or
personal computers may overload the CNC,
reducing the communication speed.
Operation on the FOCAS2/Ethernet setting screen
On the Ethernet parameter setting screen, set the parameters for
operating the FOCAS2/Ethernet function.
Procedure
1 Press the function key
SYSTEM
.
2 Soft keys [EMBED] and [PCMCIA LAN] appear.
(When there is no soft keys, press the continue key.)
3 To display the Ethernet Setting screen for the embedded Ethernet
port or the PCMCIA Ethernet card, press soft key [EMBED] or
[PCMCIA LAN], respectively.
4 Press soft keys [COMMON] and [FOCAS2] and then enter
parameters for the items that appear.
NOTE
1 The parameters for the embedded Ethernet port
and the parameters for the PCMCIA Ethernet card
are independent of each other.
2 The settings of the FOCAS2/Ethernet function for
the PCMCIA Ethernet card are made when a
connection to the Servo Guide and FANUC
LADDER-III is established.