B-63943EN-1/02-04
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
3/5
Date
Design
Descri
tion
Date
FANUC Series 30i/31i-A, 31i-A5
Continuous High-Speed Skip Function
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
6200 SRE HSS
[Input Type] Parameter Input
[Data Type] Bit path
# 4 HSS
0 : The skip function does not use high-speed skip signals.
1 : The skip function uses high-speed skip signals.
# 6 SRE When a high-speed skip signal is used:
0 : The signal is considered to be input at the rising edge (0 → 1).
1 : The signal is considered to be input at the falling edge (1→ 0).
#7 #6 #5 #4 #3 #2 #1 #0
6201 CSE
[Input Type] Parameter Input
[Data Type] Bit path
# 5 CSE For continuous high-speed skip command G31 P90, high-speed skip
signals are :
0 : Effective at either a rising or falling edge (depending on the setting of bit 6 (SRE) of
parameter No. 6200)
1 : Effective for both the rising and falling edges
#7 #6 #5 #4 #3 #2 #1 #0
6208 9S8 9S7 9S6 9S5 9S4 9S3 9S2 9S1
[Input Type] Parameter Input
[Data Type] Bit path
9S1 to 9S8 Specify valid high-speed skip signals for high-speed skip command G31P90.
Set each bit as follows:
0 : The corresponding skip signal is invalid.
1 : The corresponding skip signal is valid.
The bits correspond to signals as follows: