1.AXIS CONTROL B-63943EN-1/02
- 152 -
# 4 APZx Machine position and position on absolute position detector when the
absolute position detector is used
0 : Not corresponding
1 : Corresponding
NOTE
1 If the following parameters is modified, the parameter
APZ (No.1815#4) will be changed to "0".
No.1803#7, No.1815#1, No.1820, No.1821, No.1822,
No.1823, No.1874, No.1875, No.2022, No.2084, No.2085
2 The parameter APZ (No.1815#4) is kept value "1" even if
the grid shift value is modified.
# 5 APCx Position detector is
0 : other than an absolute position detector.
1 : an absolute position detector (absolute pulse coder).
NOTE
In case of using this function, this parameter is set
to "1".
1874 Numerator of the conversion coefficient for inner pulse coder
1875 Denominator of the conversion coefficient for inner pulse coder
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] word axis
[Unit of data]
[Valid data range] 1 to 32767
Set a conversion coefficient for the Temporary Absolute Coordinate
Setting for each axis.
The value set is determined as follows :
No.1874 Number of position feedback pulses per motor revolution
No.1875 1,000,000
#7 #6 #5 #4 #3 #2 #1 #0
2011 XIAx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be