B-63943EN-1/02 17.PMC CONTROL FUNCTION
- 1943 -
Signal list (Related signals)
Number Symbol Signal name
(1) *+ED1 to *+ED8
*- ED1 to *- ED8
External deceleration signal 1
(2) *+ED21 to *+ED28
*- ED21 to *- ED28
External deceleration signal 2
(3) *+ED31 to *+ED38
*- ED31 to *- ED38
External deceleration signal 3
(4) *HROV 1% rapid traverse override select signal
(5) HROV0 to 6 1% rapid traverse override signals
(6) *FHROV 0.1% rapid traverse override select signal
(7) FHRO0 to 9 0.1% rapid traverse override signals
(8) ROV1, 2 Rapid traverse override signals
(9) ZP1 First reference position return completion
signal
(10) ZP2 Second reference position return completion
signal
(11) ZP3 Third reference position return completion
signal
(12) ZP4 Fourth reference position return completion
signal
(13) NDCAL1 to NDCAL32 A/B phase detector disconnection alarm
ignore signal
Signal address
The method of counting the addresses of the input/output signals G
and F is described below. (See Table 17.1.1 (b) Allocation of
group-by-group signals.)
For group-by-group signals, the addresses of group 5 and up are
determined in such a way that 1000 is incremented for every four
groups.
For axis-by-axis signals, the addresses of the 9th axis and up are
determined in such a way that 1000 is incremented for every eight
axes.
Example:
The address of the EBUFg signal for group 10 is G2154.7.
The address of the EAX signal for the 14th axis is G1136.5.
Signal Detail
Each signal is detailed below.
"<>" in the title of each signal indicates a signal address. For
group-by-group signals, addresses for group 1 to group 4 are indicated.
For axis-by-axis signals, addresses for the 1st axis to 8th axis are
indicated.