B-63943EN-1/02 13.PROGRAM COMMAND
- 1749 -
1627 FL rate for acceleration/deceleration in threading cycles for each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set an FL feedrate for acceleration/deceleration after interpolation in
the threading cycles G92 and G76 for each axis. Set 0 at all times
except in a special case.
#7 #6 #5 #4 #3 #2 #1 #0
CFR
1611
[Input type] Parameter input
[Data type] Bit path
# 0 CFR For retraction after threading in the threading cycles G92 and G76:
0: The type of acceleration/deceleration after interpolation for
threading is used together with the threading time constant
(parameter No. 1626) and FL feedrate (parameter No. 1627).
1: The type of acceleration/deceleration after interpolation for rapid
traverse is used together with the rapid traverse time constant and
FL feedrate.
NOTE
When this parameter is set to 1, an in-position check is
made before retraction. For retraction, the rapid
traverse rate (parameter No. 1420) is used, regardless
of the setting of parameter No. 1466. When this
parameter is set to 0, parameter No. 1466 is used as
the feedrate for retraction. As acceleration/deceleration
used for retraction, only acceleration/deceleration after
interpolation is used. Rapid traverse before look-ahead
interpolation and optimum torque
acceleration/deceleration are disabled.
Alarm and message
Number Message Description
PS0330 ILLEGAL AXIS COMMAND IS IN THE
TURNING CANNED CYCLE
An axis other than the plane is specified n a canned cycle(G90,
G92, or G94).
Reference item
Manual name Item name
Cutting feed
Constant lead threading
USER’S MANUAL
(B-63944EN)
Multiple threading