17.PMC CONTROL FUNCTION B-63943EN-1/02
- 2052 -
Abnormal end signal MCSP <Fn512.2>
[Classification] Output signal
[Function] This signal notifies the sequence of the macro call is terminated
abnormally.
[Output condition] This signal is set to "1" in the following case:
- When the sequence is interrupted by reset or emergency stop or
alarm.
This signal is set to "0" in the following case:
- When the mode change completion signal (MCFIN) becomes "1",
and the sequence is completed.
Call program confirmation signal MCEXx <Fn514.0 toFn515.7>
[Classification] Output signal
[Function] This signal notifies the program number called by the macro call.
The signal which corresponds to macro call start signal (MCSTx) is
output.
[Output condition] This signal is set to "1" in the following case:
- While executing the sequence.
This signal is set to "0" in the following case:
- When the sequence is completed.
Signal Address
#7 #6 #5 #4 #3 #2 #1 #0
Gn512
MCST8 MCST7 MCST6 MCST5 MCST4 MCST3 MCST2 MCST1
#7 #6 #5 #4 #3 #2 #1 #0
Gn513
MCST16 MCST15 MCST14 MCST13 MCST12 MCST11 MCST10 MCST9
#7 #6 #5 #4 #3 #2 #1 #0
Gn514
MCFIN
#7 #6 #5 #4 #3 #2 #1 #0
Fn512
MCSP MCRQ MCEXE
#7 #6 #5 #4 #3 #2 #1 #0
Fn513
ZRNR DNCIR MD4R MD2R MD1R
#7 #6 #5 #4 #3 #2 #1 #0
Fn514
MCEX8 MCEX7 MCEX6 MCEX5 MCEX4 MCEX3 MCEX2 MCEX1
#7 #6 #5 #4 #3 #2 #1 #0
Fn515
MCEX16MCEX15 MCEX14MCEX13MCEX12MCEX11MCEX10 MCEX9
Parameter
6095 The number of programs used by the macro call function
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to 16
Specify the number of programs used by the macro call function.
For instance, when three is set, macro call start signal MCST1,
MCST2, and MCST3 is valid.
When “0” is specified, this function is invalid.