B-63943EN-1/02 1.AXIS CONTROL
- 235 -
Alarm and message
Number Message Description
PS0372 REFERENCE RETURN
INCOMPLETE
An attempt was made to perform an automatic return to the
reference position on the orthogonal axis before the completion
of a return to the reference position on the angular axis.
However, this attempt failed because a manual return to the
reference position during angular axis control or an automatic
return to the reference position after power-up was not
commanded. First, return to the reference position on the
angular axis, then return to the reference position on the
orthogonal axis.
PS0375 CAN NOT ANGULAR
CONTROL(SYNC:MIX:OVL)
Angular axis control is disabled for this axis configuration.
1) When some related axes under angular axis control are not
in synchronous control mode or when one angular axis is not
paired with the other angular axis or one Cartesian axis is
not paired with the other Cartesian axis in synchronous
control
2) When some related axes under composite control are not in
composite control mode or when one angular axis is not
paired with the other angular axis or one Cartesian axis is
not paired with the other Cartesian axis in composite control
3) When related axes under angular axis control is switched to
superposition control mode1)
Diagnosis
306 Machine coordinates on the angular axis in the Cartesian coordinate system
307 Machine coordinates on the perpendicular axis in the Cartesian coordinate
system
[Data type] Real number
[Unit of data] Machine unit
Machine coordinates in the Cartesian coordinate system are displayed
in angular axis control.
Bit 7 (ADG) of parameter No. 8201 can be used to change the display
order.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Angular axis control