B-63943EN-1/02-01
Edit
Apprv.
Design
Sheet
Title
Draw
No.
112/126
Date
Design
Descri
tion
Date
FANUC Se
ies 30i/31i/32i-
, 31i-
5
PMC Axis Control
2004.10.7
3010 Time lag in strobe signals MF, SF, TF, and BUFFER
[Input type] Parameter input
[Data type] Word path
[Unit of data] msec
[Valid data range] 0 to 32767
The time required to send strobe signals MF, SF, TF, and BF after the M, S, T, and B
codes are sent, respectively.
M, S, T, B code
MF, SF, TF, BF,
signal
Dela
time
NOTE
The time is counted in units of 4 ms. If the set value is not a multiple of
four, it is raised to the next multiple of four
Example
When 30 is set, 32 ms is assumed.
When 0 is set, 4 ms is assumed.
The time count period may change, depending on the system.
3011 Acceptable width of M, S, T, and B function completion signal (FIN)
[Input type] Parameter input
[Data type] Word path
[Unit of data] msec
[Valid data range] 0 to 32767
Set the minimum signal width of the valid M, S, T, and B function completion signal (FIN).
M, S, T, B code
MF, SF, TF, BF signal
FIN sigal
Ignored because shorter
than min. signal width
Valid because longer
than min. signal width