13.PROGRAM COMMAND B-63943EN-1/02
- 1690 -
Note
NOTE
1 If the CNC enters the clear state (see parameter CLR (No. 3402#6)) when the
power is turned on or the CNC is reset, the modal G codes change as follows.
(1) G codes marked with in Table 13.2 are enabled.
(2) When the system is cleared due to power-on or reset, whichever specified,
either G20 or G21, remains effective.
(3) Parameter G23 (No. 3402#7) is used to specify whether G22 or G23 is to
be selected upon power-on. The selection of G22 or G23 is not, however,
changed when the CNC is cleared upon a reset. When the system is
cleared due to reset, whichever specified, either G22 or G23, remains
effective.
2 G codes of group 00 except G10 and G11 are single-shot G codes.
3 Alarm PS0010 is displayed when a G code not listed in the G code list is
specified or a G code without a corresponding option is specified.
4 G codes of different groups can be specified in the same block.
If G codes of the same group are specified in the same block, the G code
specified last is valid.
5 If a G code of group 01 is specified in a canned cycle, the canned cycle is
canceled in the same way as when a G80 command is specified. G codes of
group 01 are not affected by G codes for specifying a canned cycle.
6 When G code system A is used for a canned cycle, only the initial level is
provided at the return point.
7 G codes are displayed for each group number.
Reference item
Manual name Item name
Preparatory function (G function) USER’S MANUAL
(B-63944EN)
Status when turning power on, when clear and
when reset