12.TOOL FUNCTIONS B-63943EN-1/02
- 1570 -
5014 Maximum value of incremental input for tool wear compensation
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch (offset unit)
[Minimum unit of data] The increment system of a tool offset value is followed.
[Valid data range] The settings of bits 3 to 0 (OFE, OFD, OFC, and OFA) of parameter
No. 5042 are followed.
For metric input
OFE OFD OFC OFA Valid data range
0 0 0 1 0to9999.99mm
0 0 0 0 0to9999.999mm
0 0 1 0 0to9999.9999mm
0 1 0 0 0to9999.99999mm
1 0 0 0 0to999.999999mm
For inch input
OFE OFD OFC OFA Valid data range
0 0 0 1 0to999.999inch
0 0 0 0 0to999.9999inch
0 0 1 0 0to999.99999inch
0 1 0 0 0to999.999999inch
1 0 0 0 0to99.9999999inch
Set the maximum allowable value for the tool wear compensation
value, input as an incremental value. If the incremental input value
(absolute value) exceeds the set value, the following alarm or warning
message is output:
Input from MDI
Warning: Too many digits
Input by G10
Alarm PS0032: Offset value is out of range by G10.
When 0 or a negative value is set, no maximum allowable value is
applied.
Alarm and message
Number Message Description
PS0032 ILLEGAL OFFSET VALUE IN G10 In setting an offset amount by G10 or in writing an offset amount
by system variables, the offset amount was excessive.
Warning message Description
DATA IS OUT OF RANGE The value searched exceeds the
permitted range.
TOO MANY DIGITS
The input value exceeds the permitted
number of digits.