B-63943EN-1/02 4.REFERENCE POSITION ESTABLISHMENT
- 509 -
Note
NOTE
1 Multiple axes cannot be selected simultaneously.
2 This cycle is not executed if either of the following conditions
is satisfied:
(A) Automatic operation signal OP <F000#7> is set to 1
(B) The direction of reference position return (bit 5 (ZMIx) of
parameter No. 1006) does not agree with the sign of a
reference position setting distance (parameter No. 7181
or 7182).
3 During cycle operation, excess error, feed stop, and feed hold
in the moving and stopped states are not checked.
4 During withdrawal operation, the torque limit is effective, but
the tool is not butted when the limit is reached. The torque
limit is released after the reference position is established.
5 When the RESET signal is input during cycle operation,
operation stops, but the torque limit is not released.
6 This function cannot be used together with the grid shift
function or reference position shift function.
7 This function cannot be used for angular, synchronous, Cs,
spindle positioning, or index table indexing axis.
8 Acceleration/deceleration is applied for this function in the
same way as for manual reference position return.
9 When this function is used and the manual reference position
return mode is selected, feed axis and direction selection
signals (such as +J1 and -J1) must be disabled.