1.AXIS CONTROL B-63943EN-1/02
- 222 -
2021 Load inertia ratio
[Input type] Parameter input
[Data type] Word axis
[Valid data range] 0 to 32767
2022 Motor rotation direction
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word axis
[Valid data range] -111 to 111
This parameter sets the direction in which the motor rotates.
When the master axis and slave axis rotate in opposite directions each
other, this parameter is used for switching.
Alarm and message
Number Message Description
SV1055 ILLEGAL TANDEM AXIS The setting of parameter No. 1023 is invalid for tandem
control.
SV1056 ILLEGAL TANDEM PAIR The setting of parameter No.1020, 1025, or 1026 or bit 6
(TDM) of parameter No. 1817 is invalid for tandem control.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Tandem control