4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 506 -
Manual reference position return
mode
Manual handle feed axis select
signals HS1A to HS1D
utomatic operation start
signal ST
Cycle operation
utomatic operation signal OP
Reference position return
end signals ZP1 to ZP8
Torque limit
xis feedrate
Torque limit reach signals for
reference position setting
with mechanical stopper
CLRCH1 to CLRCH8
100% 100%
N%
Butting direction
Withdrawal
direction
N%: Torque limit (%) specified with parameter No. 7186 (%)
- Cycle operation after the reference position has been established
When the reference position has been established, cycle operation is
not performed by operations for reference position setting with a
mechanical stopper. In this case, the tool is positioned to the
reference position in the rapid traverse mode. After the completion
of the positioning, the relevant reference position return end signal is
set to 1.
This signal is not set to 1 during automatic operation.
Signal
Torque limit reach signals for reference position setting with mechanical stopper CLRCH1
to CLRCH8 <Fn180>
[Classification] Output signal
[Function] These signals are used to post notification of the torque limit having
been reached for each corresponding axis during cycle operation for
reference position setting with mechanical stopper.
[Output condition] Each signal is set to 1 when:
- The torque limit is reached for the corresponding axis during
cycle operation for reference position setting with mechanical