B-63943EN-1/02 1.AXIS CONTROL
- 233 -
# 6 A53 So far, if a slanted axis is singly specified by a machine coordinate
command (G53) in angular axis control, this parameter set to 0
specifies that "compensation is applied to the Cartesian axis", and this
parameter set to 1 specifies that "a movement is made along the
slanted axis only". However, the specification has been changed so
that "a movement is made along the slanted axis only", regardless of
whether this parameter is set to 0 or 1.
# 7 ADG The contents of diagnostic data Nos. 306 and 307 are:
0: Not swapped. The slanted axis and Cartesian axis are displayed
in this order.
1: Swapped. The Cartesian axis and slanted axis are displayed in
this order.
CAUTION
1 After angular axis control parameter setting, be sure to perform manual reference
position return operation.
2 Before manual reference position return operation is performed along the
perpendicular axis, reference position return operation along the angular axis must
be completed (with the reference position return completion signal for the angular
axis (ZPx) set to 1). If reference position return operation is performed along the
perpendicular axis first, an alarm (PS0372) is issued.
3 When the setting is made so that the tool moves along the perpendicular axis
during manual reference position return along the slanted axis (bit 2 (AZK) of
parameter No. 8200 is set to 0), if once manual reference position return has been
performed along the angular axis, also perform manual reference position return
along the perpendicular axis immediately after the operation.
4 Before attempting to manually move the tool along the angular and perpendicular
axes simultaneously, set perpendicular/angular axis control disable signal NOZAGC
to 1.
5 Once the tool has been moved along the angular axis when perpendicular/angular
axis control disable signal NOZAGC has been set to 1, manual reference position
return must be performed.
6 The same increment system must be used with the angular axis and perpendicular
axis.
7 Before a perpendicular axis reference position return check can be made, angular
axis reference position return operation must be completed.
8 No rotary axis must be set for the angular axis and perpendicular axis. A rotary axis
may be specified only for a linear axis.
9 Set a position switch operation range (parameter Nos. 6930 to 6965) in a slanted
coordinate system.