B-63943EN-1/02 1.AXIS CONTROL
- 71 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3605 IPC
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be turned
off before operation is continued.
# 2 IPC Interpolated straightness compensation function is:
0: Not used.
1: Used.
5711 Straightness compensation : Axis number of moving axis 1
5712 Straightness compensation : Axis number of moving axis 2
5713 Straightness compensation : Axis number of moving axis 3
5714 Straightness compensation : Axis number of moving axis 4
5715 Straightness compensation : Axis number of moving axis 5
5716 Straightness compensation : Axis number of moving axis 6
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 0 to Number of controlled axes
Set the axis numbers of moving axes for straightness compensation.
When 0 is set, compensation is not performed.
5721
Straightness compensation :
Axis number of compensation axis 1 for moving axis 1
5722
Straightness compensation :
Axis number of compensation axis 2 for moving axis 2
5723
Straightness compensation :
Axis number of compensation axis 3 for moving axis 3
5724
Straightness compensation :
Axis number of compensation axis 4 for moving axis 4