14.DISPLAY/SET/EDIT B-63943EN-1/02
- 1792 -
# 3 OP4 JOG feedrate override select, feedrate override select, and rapid
traverse override select on software operator's panel
0: Not performed
1: Performed
# 4 OP5 Optional block skip select, single block select, machine lock select,
and dry run select on software operator's panel
0: Not performed
1: Performed
# 5 OP6 Protect key on software operator's panel
0: Not performed
1: Performed
# 6 OP7 Feed hold on software operator's panel
0: Not performed
1: Performed
#7 #6 #5 #4 #3 #2 #1 #0
3002 IOV
[Input type] Parameter input
[Data type] Bit path
# 4 IOV Override-related signal logic is:
0: Used without modification
(A signal of negative logic is used as a negative logic signal, and
a signal of positive logic is used as a positive logic signal.)
1: Inverted
(A signal of negative logic is used as a positive logic signal, and
a signal of positive logic is used as a negative logic signal.)
The signals indicated below are affected.
Signal of negative logic:
Feedrate override signals *FV0 to *FV7<G0012>
Second feedrate override signals*AFV0 to *AFV7<G0013>
Feedrate override signals (for PMC axis control)
*EFOV0g to *EFOV7g<G0151/G0163/G0175/G0187>
Software operator’s panel signals *FV0O to *FV7O<F0078>
Signals of positive logic:
Rapid traverse override signals ROV1,ROV2<G0014 bit0,bit1>
Software operator’s panel signals ROV1O,ROV2O<F0076 bit4,bit5>
Rapid traverse override signals (for PMC axis control)
EROV1g,EROV2g<G0150#0, #1, G0162#0, #1, G0174 #0, #1,