11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1428 -
#7 #6 #5 #4 #3 #2 #1 #0
5201 OV3 OVU TDR
[Input type] Parameter input
[Data type] Bit path
# 2 TDR Cutting time constant in rigid tapping
0: Uses a same parameter during cutting and extraction (Parameter
Nos. 5261 through 5264)
1: Not use a same parameter during cutting and extraction
Parameter Nos. 5261 to 5264: Time constant during cutting
Parameter Nos. 5271 to 5274: Time constant during extraction
# 3 OVU The increment unit of the override parameter (No.5211) for tool rigid
tapping extraction is:
0: 1%
1: 10%
# 4 OV3 A spindle speed for extraction is programmed, so override for
extraction operation is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
5202 ORI
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 ORI When rigid tapping is started:
0: Spindle orientation is not performed.
1: Spindle orientation is performed.
This parameter can be used only for a serial spindle.
This spindle orientation performs reference position return in the serial
spindle/servo mode. The stop position can be changed using the serial
spindle parameter No. 4073.