8.MULTI-PATH CONTROL B-63943EN-1/02
- 866 -
Distance along the X axis between the reference positions of tool posts 1
and 2
8151
Distance along the Z axis between the reference positions of tool posts 1
and 2
8152
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
These parameters are used for checking the interference between two
paths when bit 7 (IPF) of parameter No. 8140 is set to 0.
Each of these parameters sets the distance between the tool posts of
two paths.
Tool post 2
Tool post 1
+X
+Z
ε
In the Z-X plane coordinate system with its origin at the represent position of tool post
1, set the X component value
ε
of the reference position of tool post 2 in parameter
No. 8151 and set the Z component value
ξ
in parameter No. 8152.
Reference
point
Reference
point
WARNING
After modifying the parameter values, perform a
manual reference position return operation for both
tool posts. Otherwise, the internally stored
positional relationships of the two tool posts are not
updated to the newly set parameter values.