13.PROGRAM COMMAND B-63943EN-1/02
- 1770 -
NOTE
1 The position display represents the coordinate
value after scaling.
2 When a mirror image was applied to one axis of the
specified plane, the following results:
(1) Circular command
......................... Direction of rotation is reversed.
(2) Cutter/tool nose radius compensation
................................ Offset direction is reversed.
(3) Coordinate system rotation
................................. Rotation angle is reversed.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
5400 SCR XSC
[Input type] Parameter input
[Data type] Bit path
# 6 XSC The setting of a scaling magnification (axis-by-axis scaling) is:
0: Disabled.
1: Enabled.
# 7 SCR Scaling (G51) magnification unit
0: 0.00001 times (1/100,000)
1: 0.001 times
#7 #6 #5 #4 #3 #2 #1 #0
5401 SCLx
[Input type] Parameter input
[Data type] Bit axis
# 0 SCLx Scaling on this axis
0: Invalidated
1: Validated
5411 Scaling (G51) magnification
[Input type] Setting input
[Data type] 2-word path
[Unit of data] 0.001 or 0.00001 times (Selected using SCR, #7 of parameter
No.5400)
[Valid data range] 1to999999999
This parameter sets a scaling magnification when axis-by-axis scaling
is disabled (with bit 6 (XSC) of parameter No. 5400 set to 0). If no
scaling magnification (P) is specified in the program, the setting of
this parameter is used as a scaling magnification.