16.MEASUREMENT B-63943EN-1/02
- 1866 -
6287 Positional deviation limit in torque limit skip
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 327670
This parameter sets a positional deviation limit for each axis imposed
when torque limit skip is specified. When the actual positional
deviation exceeds the positional deviation limit, the alarm (SV0004) is
issued and an immediate stop takes place.
Alarm and message
Number Message Description
PS0035 CAN NOT COMMANDED G31 - G31 cannot be specified. This alarm is generated when a G code
(such as for cutter or tool-nose radius compensation) of
group 07 is not canceled.
- A torque limit skip was not specified in a torque limit skip command
(G31P98 or P99). Specify the torque limit skip in the PMC window
or the like. Or, specify the torque limit override by address Q.
PS0369 G31 FORMAT ERROR - No axis is specified or tow or more axes are specified in the torque
limit switch instruction (G31P98/P99).
- The specified torque Q value in the torque limit switch instruction is
out of range. The torque Q range is 1 to 99.
SV0004 EXCESS ERROR (G31) The amount of positional deviation during torque limit skip command
operation exceeded the limit value of the parameter No.6287.