12.TOOL FUNCTIONS B-63943EN-1/02
- 1606 -
Life expiration signal TMFNFD<Fn315#6>
[Classification] Output signal
[Function] This signal indicates whether a valid tool whose life still remains is
left among the tools having the type number specified by a T code.
[Output condition] This signal turns to "1" in the following cases:
When a T code is specified, the tools having the type number
specified by the T code include no valid tool whose life still
remains.
NOTE
In this case, it is necessary for the PMC to stop the
operation by issuing an external alarm and request
a tool change. If the selected tool is used
continuously with no alarm issued, the life of the
tool is counted up. The tool (cartridge and pot)
selected by the CNC at this time is a tool having the
largest tool management data number among the
tools having a specified tool type number.
This signal turns to "0" in the following cases:
- When a T code is specified, the tools having the type number
specified by the T code include a valid tool whose life still
remains.
NOTE
This signal is valid when bit 6 (NAM) of parameter
No. 13200 is set to 1.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn048 TLRST TLRSTI TLSKP
Gn049 *TLV7 *TLV6 *TLV5 *TLV4 *TLV3 *TLV2 *TLV1 *TLV0
Gn050 *TLV9 *TLV8
Gn328 TLRSI4 TLRSI3 TLRSI2 TLRSI1 TLRST4 TLRST3 TLRST2 TLRST1
Gn329 TLNCT4 TLNCT3 TLNCT2 TLNCT1 TLSKP4 TLSKP3 TLSKP2 TLSKP1
#7 #6 #5 #4 #3 #2 #1 #0
Fn026 T07 T06 T05 T04 T03 T02 T01 T00
Fn027 T15 T14 T13 T12 T11 T10 T09 T08
Fn028 T23 T22 T21 T20 T19 T18 T17 T16
Fn029 T31 T30 T29 T28 T27 T26 T25 T24