B-63943EN-1/02 1.AXIS CONTROL
- 17 -
Limitation
- Feedrate
A radius-based feedrate is specified in both of diameter specification
and radius specification at all times.
- Data not switchable
The following data follows the setting of parameter DIAx, so that
diameter/radius specification switching is not performed:
- Parameter
- Offset
- Workpiece coordinate system
- Scale display on the graphic screen
NOTE
For offset data, the settings of bit 1 (ORC) of parameter
No. 5004 and bit 2 (ODI) of parameter No. 5004 have
priority.
- Switchable data and commands
For the following data and commands, diameter/radius specification
switching is performed according to the specified specification
method:
- Programmed move command
- Current position display
- Workpiece coordinate system preset
- Movement based on the manual numeric command G00 or G01
- Use with other functions
1) Diameter/radius specification switching cannot be performed for
an axis on which a movement is being made with any of the
functions indicated below.
Moreover, none of the functions indicated below can be
performed during diameter/radius specification switching.
- Synchronous/mixture control
- Superimposed Control
- Axis synchronous control
- PMC axis control
2) This function is ignored and inoperative when the following
function is performed:
- Background graphic