2.PREPARATIONS FOR OPERATION B-63943EN-1/02
- 334 -
- Alarms OT0506, OT0507 : Hard OT
- Alarms OT0510, OT0511 : Stored stroke check before movement
Once the signal is set to 1, the axis and direction of the signal are
stored. It is impossible to further move the tool along that axis in
that direction. The tool can be moved along the axis only in the
direction opposite to the stored direction. Moving the axis in the
opposite direction resets the signal to 0.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn007 RLSOT EXLM
Gn104 +EXL8 +EXL7 +EXL6 +EXL5 +EXL4 +EXL3 +EXL2 +EXL1
Gn105 -EXL8 -EXL7 -EXL6 -EXL5 -EXL4 -EXL3 -EXL2 -EXL1
Fn124 +OT8 +OT7 +OT6 +OT5 +OT4 +OT3 +OT2 +OT1
Fn126 -OT8 -OT7 -OT6 -OT5 -OT4 -OT3 -OT2 -OT1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1300 BFA LMS NAL
[Input type] Setting input
[Data type] Bit path
# 1 NAL When the tool enters the inhibition area of stored stroke limit 1:
0: The overtravel alarm signal is not output.
1: The overtravel alarm signal is output, and the tool is decelerated
to a stop.
If manual operation is in progress at this time, the alarm is not
output.
NOTE
When this parameter is set to 1, the alarm is issued
if the tool enters stored stroke limit 1 during
automatic operation.
# 2 LMS The EXLM signal for switching stored stroke check
0: Disabled
1: Enabled
When bit 0 (DLM) of parameter No. 1301 is set to 1, the stored stroke
check 1 switch signal EXLM (G007#6) is made invalid.