B-63943EN-1/02 3.MANUAL OPERATION
- 445 -
Manual handle generators selection signal IOLBH1 <G199.0>, IOLBH2 <G199.1>
[Classification] Input signal ( common among paths )
[Function] This signal selects the manual handle generator which operates the I/O
Link β.
[Operation] This signal selects the manual handle generator which operates the I/O
Link β.
IOLBH2 IOLBH1 Manual handle generator which operates I/O
Link β
0 0 First unit
0 1 Second unit
1 0 Third unit
CAUTION
Please don’t change the manual handle generator on the
manual handle mode.
Signals on I/O Link β side
No. #7 #6 #5 #4 #3 #2 #1 #0
Yy+0 MD4 MD2 MD1
Yy+7 MP2 MP1
Signals on CNC
No. #7 #6 #5 #4 #3 #2 #1 #0
G199 IOLBH2 IOLBH1
Parameter
- Parameter on I/O Link β side
No. #7 #6 #5 #4 #3 #2 #1 #0
005 MP IOH
[Data type] Bit
# 4 IOH Manual handle feed by way of I/O Link is :
0 : Unavailable
1 : Available
CAUTION
Please be sure to set the parameter EXPLS
(No.0003#6) on the I/O Link β to 0, when IOH is set
to 1.
# 5 MP On the manual handle feed, 4 kinds of magnifications set by the signal
MP1/MP2 are :
0 : Unavailable
1 : Available